Cambridge O Level Physics 5054/32 Oct/Nov 2025 Paper 3 Practical: Interactive Worked Solutions & Sample Lab Data
Complete step-by-step practical guide, authentic laboratory dataset, vector apparatus diagrams, and 4-layer analytical scaffolding aligned with the official October/November 2025 Mark Scheme (Maximum Mark: 40).
Question 1: Investigating a Light Dependent Resistor (LDR)
10 MarksIn this experiment you will investigate a light dependent resistor (LDR). You are provided with a power supply ($3.0\text{ V}$ DC), a switch, a voltmeter with two leads, a light dependent resistor (LDR), a $560\ \Omega$ fixed resistor, and a piece of card.
The supervisor has constructed a series circuit consisting of the power supply, the LDR, the resistor and the switch. The circuit has three points labelled P, Q and S.
Select the correct combination of components and arrangement for the circuit diagram:
💡 Layer 1: Conceptual Orientation
How are components connected in a series circuit? Look carefully at the list of components in the supervisor's circuit: does the voltmeter belong in the permanent series loop, or is it connected separately across points later?
Also distinguish between an LDR (arrows pointing towards the resistor) and an LED (arrows pointing away from a diode).
🔍 Layer 2: Method & Analytical Guide
- Draw a single continuous rectangular loop with no branches.
- Insert the power supply symbol (two small circles with $+$ and $-$ signs) at the top.
- Insert the open switch symbol, the fixed resistor (plain rectangle), and the LDR symbol (rectangle with two parallel arrows pointing inwards).
- Do not include any extra components (such as the voltmeter or ammeter) in this base circuit diagram.
✅ Layer 3: Full Worked Solution & Mark Scheme
- Any series circuit drawn with unbroken loop [B1]
- Series circuit showing power supply, switch, LDR, resistor and no other components, connected in series with all symbols correct [B1]
- (b)(i) Connect the voltmeter across the LDR between points P and Q under normal lighting conditions. Close the switch and record $V_{\text{PQ}}$. [1]
- (b)(ii) Reconnect the voltmeter across the $560\ \Omega$ resistor between points Q and S. Close the switch and record $V_{\text{QS}}$. [1]
- (c) Calculate the current $I$ in the circuit using $I = \dfrac{V_{\text{QS}}}{R}$, where $R = 560\ \Omega$. [1]
- (d) Calculate the resistance $R_{\text{LDR}}$ of the LDR under normal lighting conditions using $R_{\text{LDR}} = \dfrac{V_{\text{PQ}}}{I}$. [1]
- (e) Reconnect the voltmeter across P and Q, place the piece of card on top of the LDR (in the dark), and record the new value of $V_{\text{PQ}}$. [1]
- (b)(i) Under normal laboratory lighting, voltmeter reading across LDR (P and Q): $V_{\text{PQ}} = 1.6\text{ V}$
- (b)(ii) Under normal laboratory lighting, voltmeter reading across $560\ \Omega$ resistor (Q and S): $V_{\text{QS}} = 1.4\text{ V}$
- (e) With the card placed directly on top of the LDR (in the dark), voltmeter reading across P and Q: $V_{\text{PQ (dark)}} = 2.7\text{ V}$
💡 Layer 1: Conceptual Orientation
In a series potential divider circuit connected to a $3.0\text{ V}$ supply, the sum of the potential differences across the LDR and the fixed resistor equals the supply e.m.f.: $V_{\text{PQ}} + V_{\text{QS}} \approx 3.0\text{ V}$.
Why is the current $I$ through the LDR exactly the same as the current calculated through the $560\ \Omega$ resistor?
🔍 Layer 2: Method & Analytical Guide
- For 1(b)(i) & (ii): Voltmeter readings must be recorded to at least $0.1\text{ V}$ precision, with $V_{\text{PQ}} \le 3.0\text{ V}$ and $V_{\text{QS}} < V_{\text{PQ}}$ (or consistent with the room lighting and supply voltage).
- For 1(c): Substitute $V_{\text{QS}} = 1.4\text{ V}$ and $R = 560\ \Omega$ into $I = \dfrac{V_{\text{QS}}}{R}$.
- For 1(d): Substitute $V_{\text{PQ}} = 1.6\text{ V}$ and your calculated current $I$ into $R_{\text{LDR}} = \dfrac{V_{\text{PQ}}}{I}$.
- For 1(e): When covered by the card, light intensity drops, so the new $V_{\text{PQ}}$ across the LDR must be greater than $V_{\text{PQ}}$ in 1(b)(i) and $\le 3.0\text{ V}$.
✅ Layer 3: Full Worked Solution & Mark Scheme
- (f) Compare your reading for $V_{\text{PQ}}$ under normal lighting in (b)(i) with $V_{\text{PQ}}$ covered by card in (e). Suggest what causes the change in the voltmeter readings as the intensity of the light reaching the LDR decreases. [1]
- (g) Close the switch. Hold the card horizontally about $50\text{ cm}$ above the LDR. Slowly move the card towards the LDR until it rests on top of the LDR. Describe the changes you see to the voltmeter reading as the card is moved downwards. [2]
How does the voltmeter reading $V_{\text{PQ}}$ behave in 1(g) as the card moves down from $50\text{ cm}$ to $0\text{ cm}$?
💡 Layer 1: Conceptual Orientation
For (f): How does the resistance of a semiconductor LDR depend on light intensity?
For (g): When a small piece of card is held $50\text{ cm}$ above the bench, plenty of ambient room light still reaches the LDR from the sides. At what point does the card actually cast a dark shadow over the LDR window?
🔍 Layer 2: Method & Analytical Guide
- Part (f): State clearly what happens to the resistance of the LDR when light intensity decreases.
- Part (g): Break the description into two stages:
- Initial stage (when the card is far from the LDR, e.g., $50\text{ cm}$ down to $\sim 10\text{ cm}$).
- Final stage (when the card gets very close to and covers the LDR).
✅ Layer 3: Full Worked Solution & Mark Scheme
1(f) Model Answer:
As the light intensity decreases, the resistance of the LDR increases (so it takes a larger share of the supply voltage). [B1]
1(g) Model Answer:
- Initially, the voltmeter reading remains (more or less) constant / does not change much as the distance decreases [B1]
- Then the voltmeter reading increases (rapidly) as the card gets close to the LDR [B1]
Question 2: Absorption of Thermal Radiation by Coloured Surfaces
10 MarksIn this experiment, you will investigate the absorption of thermal radiation by different coloured surfaces. You are provided with a filament lamp connected to a power supply, a thermometer with a piece of white card attached to its bulb, a thermometer with a piece of black card attached to its bulb, a clamp, boss and stand, a stopwatch, and a $30\text{ cm}$ ruler.
The distance $d$ between the card and the lamp is adjusted to $1\text{ cm}$. The lamp is switched on and temperatures $\theta_{\text{W}}$ (white card) and $\theta_{\text{B}}$ (black card) are recorded every $60\text{ s}$ for $300\text{ s}$ in Table 2.1.
| time $t\ /\ \text{s}$ | white card temperature $\theta_{\text{W}}\ /\ ^\circ\text{C}$ | black card temperature $\theta_{\text{B}}\ /\ ^\circ\text{C}$ |
|---|---|---|
| 0 | 24.0 | 24.0 |
| 60 | 26.5 | 28.5 |
| 120 | 28.5 | 32.5 |
| 180 | 30.5 | 36.0 |
| 240 | 32.0 | 39.0 |
| 300 | 33.0 | 41.4 |
- (c)(i) Determine the temperature increase $\Delta\theta$ between $t = 0$ and $t = 300\text{ s}$ for each card. [1]
- (c)(ii) Calculate the average rate of increase of temperature of each card using $\text{average rate} = \dfrac{\Delta\theta}{t}$ where $t = 300\text{ s}$. Include the unit. [2]
💡 Layer 1: Conceptual Orientation
How do you find the total temperature rise $\Delta\theta$ over the $300\text{ s}$ heating period from Table 2.1? Look at the readings at $t = 0\text{ s}$ and $t = 300\text{ s}$.
When dividing $\Delta\theta$ (in $^\circ\text{C}$) by time $t$ (in $\text{s}$), what is the combined unit for the rate of temperature increase?
🔍 Layer 2: Method & Analytical Guide
- White card: $\Delta\theta_{\text{W}} = \theta_{\text{W}}(300) - \theta_{\text{W}}(0) = 33.0 - 24.0$. Divide by $300\text{ s}$.
- Black card: $\Delta\theta_{\text{B}} = \theta_{\text{B}}(300) - \theta_{\text{B}}(0) = 41.4 - 24.0$. Divide by $300\text{ s}$.
- Unit: Since temperature is in $^\circ\text{C}$ and time $t = 300\text{ s}$ is in seconds, the unit is $^\circ\text{C/s}$ (or $^\circ\text{C s}^{-1}$).
✅ Layer 3: Full Worked Solution & Mark Scheme
- 2(a)(i): Sensible initial room temperature recorded (e.g. $24.0\ ^\circ\text{C}$) [B1]
- 2(a)(ii): Full set of temperatures recorded for white card [B1] and temperatures increasing [B1]
- 2(b): Full set of temperatures recorded for black card with $\theta_{\text{B}} \ge \theta_{\text{W}}$ at $300\text{ s}$ and a greater $\Delta\theta$ [B1]
- (d) Use your answers to (c)(ii) to deduce a conclusion which compares the absorption of thermal radiation by the two different coloured cards. [1]
- (e) State two variables that should be controlled in this experiment to ensure a valid conclusion. [2]
Which statement gives a valid conclusion for 2(d) and two valid control variables for 2(e)?
💡 Layer 1: Conceptual Orientation
Which card experienced the higher rate of temperature increase when exposed to the same filament lamp? What does that tell us about its ability to absorb infrared (thermal) radiation?
For a fair comparison between the white and black cards, what geometric and electrical factors of the setup in Fig. 2.1 must be kept identical?
🔍 Layer 2: Method & Analytical Guide
- For (d): Link the higher rate of temperature increase ($0.058\ ^\circ\text{C/s} > 0.030\ ^\circ\text{C/s}$) to the conclusion that the black card is a better absorber of thermal radiation than the white card.
- For (e): Identify any two physical quantities held constant between the two runs (e.g. distance $d$ from lamp, lamp power/brightness, card dimensions/thickness, initial temperature).
✅ Layer 3: Full Worked Solution & Mark Scheme
2(d) Conclusion:
The black card is a better absorber of thermal radiation (infrared radiation / heat) than the white card. [B1]
2(e) Control Variables (Any two for 1 mark each): [B2]
- Same distance $d$ of card from the lamp
- Same brightness / intensity / current / voltage / power of the lamp
- Same surface area / thickness / material / size of card
- Same initial (room) temperature / allow lamp to cool between experiments
- Same height of thermometer bulb above the bench (level with filament)
Question 3: Determining the Mass of a Metre Rule by Balancing
14 MarksIn this experiment you will use a balancing method to determine the mass $M$ of a metre rule. You are provided with a metre rule with a millimetre scale, a triangular block to act as a pivot, and slotted masses making a total of $100\text{ g}$.
A mass $m$ is placed on the metre rule with its centre at the $5.0\text{ cm}$ mark. The position of the metre rule on the pivot is adjusted until it balances (Fig. 3.1).
- (a)(i) & (ii): For $m = 20\text{ g}$, record the position of the pivot $p$ (in $\text{cm}$ to the nearest $\text{mm}$), the distance $a = p - 5.0\text{ cm}$, and the distance $b = 50.0\text{ cm} - p$. [2]
- (b)(i): Repeat the procedure for $m = 40\text{ g}, 60\text{ g}, 80\text{ g}$ and $100\text{ g}$. [2]
- (b)(ii): Describe how you ensure that the centre of each mass placed on the metre rule is directly above the $5.0\text{ cm}$ mark. [1]
- (c): Calculate the ratio $r = \dfrac{b}{a}$ for each value of $m$ and record in Table 3.1. [1]
| $m\ /\ \text{g}$ | position of pivot / $\text{cm}$ | $a\ /\ \text{cm}$ | $b\ /\ \text{cm}$ | $r = \dfrac{b}{a}$ |
|---|---|---|---|---|
| 20 | 42.8 | 37.8 | 7.2 | 0.19 |
| 40 | 37.6 | 32.6 | 12.4 | 0.38 |
| 60 | 33.6 | 28.6 | 16.4 | 0.57 |
| 80 | 30.5 | 25.5 | 19.5 | 0.76 |
| 100 | 28.0 | 23.0 | 22.0 | ? (Calculate below) |
💡 Layer 1: Conceptual Orientation
As the mass $m$ at the $5.0\text{ cm}$ mark increases, which way must the pivot move to keep the rule balanced—closer to the $5.0\text{ cm}$ mark or closer to the $50.0\text{ cm}$ mark? How does this affect $a$ and $b$?
For 3(b)(ii), a slotted mass is a circular disc (~$2.6\text{ cm}$ wide) that covers the $5.0\text{ cm}$ line on the rule. How can you position its centre accurately over $5.0\text{ cm}$?
🔍 Layer 2: Method & Analytical Guide
- Precision check: Every length in Table 3.1 (pivot position, $a$, and $b$) must be recorded to $1\text{ decimal place}$ in $\text{cm}$ (nearest millimetre). Notice that $a + b = 45.0\text{ cm}$ for every row!
- Trend check: Down the table, as $m$ increases, the pivot position and $a$ decrease while $b$ and $r$ increase.
- For 3(b)(ii): Either measure the diameter $D$ of the mass and place its edges at $5.0 - D/2$ and $5.0 + D/2$, or align the central slot/hole with the $5.0\text{ cm}$ mark.
✅ Layer 3: Full Worked Solution & Mark Scheme
- 3(a)(i): Position recorded in centimetres to the nearest millimetre (e.g. $42.8\text{ cm}$) [B1]
- 3(a)(ii): $a$ and $b$ recorded and correct ($a = \text{pivot} - 5.0$, $b = 50.0 - \text{pivot}$) [B1]
- 3(b)(i): Complete set of values recorded [B1] with correct trend down table (pivot and $a$ decreasing, $b$ increasing) [B1]
- 3(b)(ii) Centering the mass (Any one of): [B1]
- Measure the diameter of the mass, divide by 2, and place the edges of the mass this distance to the left and right of the $5.0\text{ cm}$ mark (e.g. for a $2.6\text{ cm}$ wide mass, edges at $3.7\text{ cm}$ and $6.3\text{ cm}$).
- Take the scale readings at both opposite edges of the mass and ensure their mean is $5.0\text{ cm}$.
- Look vertically down through the slot in the mass and align the centre of the slot with the $5.0\text{ cm}$ mark.
- 3(c): All values of $r = b/a$ correctly calculated (for $m = 100\text{ g}$, $r = 22.0 / 23.0 = 0.96$ or $0.957$) [B1]
- (d) On the grid provided in Fig. 3.2, plot a graph of $r$ on the y-axis against $m$ on the x-axis. Start your axes from the origin $(0,0)$. Draw the straight line of best fit. [4]
- (e)(i) Calculate the gradient $G$ of your graph. Show clearly on the graph how you obtained the numbers you use. [2]
- (e)(ii) The mass $M$ of the metre rule is given by $M = \dfrac{1}{G}$. Determine $M$ to the nearest gram. [1]
- (f) A student says that the centre of gravity of the metre rule is at the $50.0\text{ cm}$ mark. Describe how you use the apparatus provided to check that this statement is correct. [1]
💡 Layer 1: Conceptual Orientation
Why does the graph pass through $(0,0)$? By the Principle of Moments about the pivot: $m g a = M g b \implies r = \dfrac{b}{a} = \left(\dfrac{1}{M}\right) m$. Thus, $r$ is directly proportional to $m$, and the gradient of $r$ against $m$ is $G = \dfrac{1}{M}$!
For 3(f): Where is the centre of gravity of an object located in terms of its balancing point when no extra masses are attached?
🔍 Layer 2: Method & Analytical Guide
- Graph Criteria (4 marks):
- Axes labelled with quantity and unit ($r$ on y-axis, $m\ /\ \text{g}$ on x-axis). Note: $r$ is a dimensionless ratio so it has no unit.
- Linear, sensible scales starting at $(0,0)$ occupying more than half the grid.
- All 5 points plotted accurately to within $\pm \frac{1}{2}$ small square.
- Single thin best-fit straight line drawn through the points.
- Gradient $G$: Choose two points on the line separated by at least half the line length ($\Delta m \ge 40\text{ g}$). Mark the triangle on the graph.
- Mass $M$: Calculate $M = \dfrac{1}{G}$ and round to the nearest whole gram.
✅ Layer 3: Full Worked Solution & Mark Scheme
3(f) Checking the Centre of Gravity:
Remove the slotted masses and place the bare metre rule on the pivot at the $50.0\text{ cm}$ mark; check to see if the metre rule balances horizontally. [B1]
Question 4: Planning an Experiment – Insulation Thickness & Rate of Cooling
6 MarksA student investigates the rate of cooling of hot water in a beaker. Plan an experiment to investigate the relationship between the thickness of the cardboard insulation wrapped around the beaker and the rate of cooling of the hot water in the beaker.
Apparatus available: a supply of hot water, a beaker, a thermometer, and a supply of $1\text{ mm}$ thick cardboard sheets.
In your plan include: any other apparatus needed, a brief description of the method (including measurements and accuracy precautions), the variables you will control, a results table (without readings), and how you will process your results to reach a conclusion.
Self-Check: Which essential piece of measuring apparatus is missing from the provided list and MUST be stated for MP1?
💡 Layer 1: Conceptual Orientation
To measure a rate of cooling ($\Delta\theta / t$), you need both temperature and time. The list includes a thermometer, so what apparatus must you add to measure time?
Since each cardboard sheet is $1\text{ mm}$ thick, how can you easily vary and know the total thickness of cardboard wrapped around the beaker?
🔍 Layer 2: Method & Analytical Guide (6-Point Checklist)
- MP1 (Additional Apparatus): State a stopwatch / timer (plus a measuring cylinder to measure water volume and rubber bands/tape to hold the cardboard).
- MP2 (Basic Method): Wrap cardboard around the beaker, pour in hot water, and measure the temperature drop over a fixed cooling time (e.g. $300\text{ s}$) using the thermometer and stopwatch.
- MP3 (Independent Variable Range): Repeat the experiment with at least 2 different thicknesses (better: 5 thicknesses, e.g., $0, 1, 2, 3, 4\text{ mm}$ by wrapping $0, 1, 2, 3, 4$ sheets of $1\text{ mm}$ cardboard).
- MP4 (Control Variables): Keep constant the initial temperature of the hot water, the volume/mass of hot water, the room temperature, and the cooling time $t$.
- MP5 (Results Table): Draw a ruled table with columns for thickness $x\ /\ \text{mm}$ (or number of sheets), initial temperature $\theta_0\ /\ ^\circ\text{C}$, final temperature $\theta_f\ /\ ^\circ\text{C}$, temperature drop $\Delta\theta\ /\ ^\circ\text{C}$, and rate of cooling in $^\circ\text{C/s}$.
- MP6 (Processing & Conclusion): Plot a graph of rate of cooling against thickness of cardboard (or temperature drop against thickness for a fixed time) to see if/how thickness affects the rate of cooling.
✅ Layer 3: Full 6-Mark Model Plan & Mark Scheme
1. Additional Apparatus Needed [MP1: 1 mark]
- A stopwatch (or stopclock / timer) to measure the cooling time.
- A measuring cylinder to measure a fixed volume of hot water, and rubber bands or sticky tape to secure the cardboard sheets tightly around the beaker.
2. Experimental Method & Accuracy Precautions [MP2 & MP3: 2 marks]
- Wrap 1 sheet of cardboard (thickness $d = 1\text{ mm}$) tightly around the sides of the beaker and secure it with rubber bands.
- Use the measuring cylinder to pour $150\text{ cm}^3$ of hot water into the beaker.
- Place the thermometer in the water, stir gently, wait until the temperature reaches a chosen starting temperature $\theta_{\text{initial}} = 80.0\ ^\circ\text{C}$, and immediately start the stopwatch.
- After a fixed cooling time of $t = 300\text{ s}$ (5 minutes), stir the water and record the final temperature $\theta_{\text{final}}$ on the thermometer, viewing the scale perpendicular to the meniscus to avoid parallax error.
- Repeat the entire procedure for at least 5 different thicknesses of cardboard: $d = 1\text{ mm}, 2\text{ mm}, 3\text{ mm}, 4\text{ mm}, \text{and } 5\text{ mm}$ (using $1, 2, 3, 4, \text{and } 5$ sheets of the $1\text{ mm}$ cardboard).
3. Control Variables [MP4: 1 mark]
- Same initial temperature of the hot water (e.g. $80.0\ ^\circ\text{C}$) for every trial.
- Same volume (or mass) of hot water (e.g. $150\text{ cm}^3$) measured with the measuring cylinder.
- Same cooling time ($300\text{ s}$), same beaker, and same room conditions (away from draughts).
4. Results Table [MP5: 1 mark]
| Number of sheets | Cardboard thickness $d\ /\ \text{mm}$ | Initial temperature $\theta_{\text{initial}}\ /\ ^\circ\text{C}$ | Final temperature after $300\text{ s}$, $\theta_{\text{final}}\ /\ ^\circ\text{C}$ | Temperature decrease $\Delta\theta\ /\ ^\circ\text{C}$ | Rate of cooling $\dfrac{\Delta\theta}{t}\ /\ (^\circ\text{C/s})$ |
|---|---|---|---|---|---|
| 1 | 1 | ||||
| 2 | 2 | ||||
| 3 | 3 | ||||
| 4 | 4 |
5. Data Processing & Conclusion [MP6: 1 mark]
- For each thickness $d$, calculate the temperature fall $\Delta\theta = \theta_{\text{initial}} - \theta_{\text{final}}$ and the average rate of cooling $\text{Rate} = \dfrac{\Delta\theta}{300\text{ s}}$.
- Plot a graph of rate of cooling (on the y-axis) against thickness of cardboard $d\ /\ \text{mm}$ (on the x-axis) (or compare the table values) to determine how the thickness of cardboard insulation affects the rate of cooling.
0 comments: